Backup power and water for complexes: who pays and who approves?
Who pays for generators, inverters, batteries and water tanks in a sectional title complex, and which resolutions PMR 29 requires before installation.
Energy and utilities
A building should size a backup generator around critical loads and manage safe placement, exhaust, ventilation, noise, fuel storage, electrical changeover and maintenance. The installation must be designed and inspected by competent professionals, with applicable municipal and safety requirements checked. A generator plan should also state who operates it, how fuel is monitored and how complaints or faults are handled.

List the equipment that must operate during an outage and distinguish essential loads from discretionary ones. Consider motor starting current, operating hours, expected outage duration and whether the generator will run alongside batteries or solar. A smaller, managed load can be safer and more economical than trying to power an entire building. Ask a qualified electrical professional to check the design, changeover arrangement, earthing and protection.
Place the generator where exhaust gases cannot enter occupied spaces or air intakes, and provide ventilation as required by the equipment design. Assess noise at nearby homes and common areas, especially during night operation, and confirm applicable local noise rules. Fuel storage and refuelling require secure, suitable arrangements that address fire risk, spills, access and environmental protection. Keep the operating area controlled, clearly labelled and accessible only to trained people.
Set an inspection and maintenance schedule consistent with manufacturer guidance and applicable requirements. Record test runs, faults, fuel checks, servicing and operating hours. Train authorised operators in safe start-up, shutdown and emergency response, and keep contact details for the service provider. For a complex, explain when the generator will run, who receives notifications and how noise or access concerns can be reported.
Check each source’s current version before acting.
A generator’s exhaust can create a serious carbon monoxide hazard. Follow the manufacturer’s placement instructions and have a competent professional assess ventilation and exhaust discharge. Never operate a portable generator in an enclosed space.
Use appropriate equipment selection, acoustic measures and a suitable location, while preserving ventilation and safe access. Check local noise requirements and plan operating times and complaint handling.
Follow the manufacturer’s guidance and the site’s maintenance plan, while considering the generator’s critical role and applicable safety requirements. Keep a record of tests, servicing and faults.
Who pays for generators, inverters, batteries and water tanks in a sectional title complex, and which resolutions PMR 29 requires before installation.
Hiring backup power installers? Trustees should use a registered electrical contractor and check fuel-storage, noise and fire requirements.
How trustees can assess water, electricity, backup power and other infrastructure issues in a complex, and when to bring in registered specialists.